Optical Characterization

规范

Eclipse Ti Inverted Optical / Dark Field Microscope (Nikon)

Eclipse Ti Inverted Optical / Dark Field Microscope (Nikon)

Our Nikon Ti-U Inverted Microscope is currently set up for brightfield, 暗视野, transmission and reflection studies.

规范

  • Orientation: Inverted
  • Light Sources: 12V 100W Halogen Lamp
  • Objectives: 10x, 20x, 40x, 60x, and 100x
  • 目镜:10倍
  • Camera: Q Imaging Retiga 2000R 1.92MP Color CCD Microscope Camera
  • Spectrometer: Stellarnet BLACK-Comet UV-Vis Spectrometer

 

 

LAMBDA 45 UV/Vis System (PerkinElmer)

LAMBDA 45 UV/Vis System (PerkinElmer)

LAMBDA 45 UV/Vis Spectrophotometer from PerkinElmer can be used for measurements on liquids, 固体, 贴, powders samples and regulatory tests requiring variable bandwidths and highly scattering light samples. The additional pre-monochromator reduces stray light by a factor of 2, providing optimum performance for turbid and light-scattering liquid samples, such as biological solutions and suspensions.

特性

  • True double beam operation for very high stability, higher accuracy and reproducibility
  • 1 nm resolution and low stray-light design easily passes all pharmacopoeia and regulatory performance tests
  • Widest range of reproducible and robust sampling accessories to simplify and speed your analysis, whatever your sample
  • Pre-aligned Deuterium and Tungsten-halogen lamps for increased uptime
  • Choice of UV WinLab software to simplify analysis from sample entry to report generation
描述 规范
范围(nm) 190-1100
Double-Beam Operation 是的
带宽(nm) 0.5 - 4(变量)
操作方式 Scanning, Wavelength Program, Timedrive, Rate, Quant, Scanning Quant
应用程序
  • Routine UV/Vis testing
  • 液体分析
  • Transparent 固体
  • Regulatory tests requiring variable bandwidths
  • Highly absorbing samples
Absorbance Range (linearity 0.99r2) 3.5A

 

Acton SP2300 Spectrometer with PIXIS:100B CCD Camera (Princeton)

Acton SP2300 Spectrometer with PIXIS:100B CCD Camera (Prince

The SP2300 from Teledyne Princeton Instruments is a Spectrometer with 波长范围 64 nm, Spectral Resolution 0.1 nm (PMT), 0.14nm (CCD).

PIXIS cameras are fully integrated, low-noise cameras with deep cooling for quantitative scientific imaging and spectroscopy from UV-NIR. High-quantum efficiency and ultra-low-noise electronics make PIXIS cameras ideal for demanding low-light applications.

  • ~120-1100 nm sensitivity
  • -90℃深冷
  • 支持 for CCDs of varying sizes
  • Flexible readout design
描述 规范
Measuring Techniques Raman Spectroscopy, Fluorescence Spectroscopy, Transmission
分光计类型 台式
波长范围 64 nm
Spectral Resolution 0.1 nm (PMT), 0.14nm (CCD)
Aperture (f-number) f/3.9
入射狭缝 10µm ~ 3mm
光栅 1200 g/mm gratings
输入焦距 300 mm
Output Focal length 300 mm
扫描范围 0 ~ 1400 nm
Wavelength accuracy ± 0.2 nm
请注意 Linear Dispersion: 2.38 nm/mm, 光栅 Size: 68 x 68 mm (68 x 84- Optional), Focal Plane Size: 27 mm wide, 14 mm high